Threephase transformer connections and vector groups for. Pdf transformer vector group test conditions k pandian. The three distinct ways by which a three phase windings can be. In a delta connected dd group of transformers, the line voltage, vl is equal to the supply voltage, vl vs. Threephase transformers can have their windings connected in various ways. Hence every electrical power transformer must undergo through vector group test of transformer at factory site for ensuring the customer specified vector group of transformer. The primary windings are connected in one of several ways.
In theory of a three phase transformer works like three equal and separated single phase transformers working separately with three phase system with shared limbs. The vector group code is composed of the following elements. Separate single phase transformers can be used and externally interconnected to yield the same results as a 3 phase unit. The determination of vector group of transformers is very important before connecting two or more transformers in parallel. This symbol indicates the winding connections and their relative phase displacement by means of a numerical index e. Three phase transformer consists of three sets of primary windings, one for each phase, and three sets of secondary windings wound on the same iron core. The connection of all the windings in a threephase transformer is indicated by a vector group symbol. The vector group indicates the phase difference between the primary and secondary sides, introduced due to that particular configuration of transformer windings connection. This video contains vector grouping of three phase transformer for starstar and deltadelta connections.
Vector group of 3phase transformer electrical concepts. The uppercase letter indicates the highervoltage winding. Some basic connections of a 3phase transformer along with the idea of vector grouping is introduced. Three phase connection of singlephase transformers introduction.
The clock method is used to produce the numerical index of the vector group. For the love of physics walter lewin may 16, 2011 duration. Vector grouping of three phase transformer part 1 duration. To connect three singlephase transformers in astardeltayd1, yd11. Three phase transformer vector grouping significance. Vector group test of power transformer electrical4u. Subscribe our electrical engineering related channel electrical academy to get the. How to draw transformer vector group connectionelectrical. This means that a 3phase transformer can have its primary and secondary windings connected the same deltadelta or starstar, or differently. Threephase transformer connections and vector groups for beginners photo credit.
The phase sequence or the order in which the phases reach their maximum. The three phase transformer windings can be connected several ways. Vector grouping of three phase transformer part 1 youtube. True threephase transformer turns ratio tester trt43a. Transformers built to ansi standards usually do not have the vector group shown on their nameplate and instead a vector diagram is given to show the relationship between the primary and other windings. So it is utmost necessary to know how the inter connections to be made to form a particular vector group. Vector grouping of a three phase transformer part1. P department of electrical and electronics engineering loyola institute of technology and science loyola nagar, thovalai, tamilnadu629302, india abstract transformer is the most important unit in an electrical distribution network.
The vector group of transformer is an essential property for successful parallel operation of transformers. Vector group is an essential characteristics of 3 phase transformer. Subscribe our electrical engineering related channe. Transformer, circuit breakers, contact resistance, tap changer. Here the magnetic circuit for the two outer limbs of the three phase transformer is lit bit longer than for the center limb of the same.